-11%
Cyberpower OLS3000EC 3000VA 2400 Watts 3KVA Online UPS
FEATURES
Online Double-conversion Topology
Cyberpower OLS3000EC 3000VA 2400 Watts 3KVA Online UPS adopts online double-conversion topology to provide the best power quality regardless of the conditions of incoming power. This topology also features a zero transfer time, ensuring optimal system operation.
When the quality of utility power is good, the UPS switches to ECO mode to increase system efficiency. When the quality is unstable, the UPS switches to line mode to guarantee the best power quality.
Color LCD Panel
The color LCD panel is designed with an intuitive and graphical user interface, allowing users to monitor the power system and configure settings with ease.
Surge-protected Outlets
The UPS outlets absorb surges and spikes caused by thunder and lightning, hence providing complete protection for equipment and devices.
Generator Compatible
Power continuity can be achieved with generators during a power outage. When UPS is running on the generator’s power, it can stabilize unstable voltages from the generator while providing reliable power.
Variable Speed Fans
The UPS is designed with a variable 20-speed fan that provides automatic thermal management based on power load to reduce noise and offer greater comfort for users.
Remote Management Capability
Remote management capability enables monitoring and controlling of devices through a Remote Management Card. Users can also perform management tasks, such as scheduled shutdowns and reboots.
PowerPanel Business Software
The PowerPanel Management Software can perform power management and system graceful shutdown. This software has achieved VMware Readyâ„¢ status and is compatible with VMware ESXi. It also supports Citrix XenServer and Microsoft Hyper-V.
PowerPanel Cloud Solution
The solution offers a convenient cloud-based management that allows users to access and monitor the UPS systems through a secure web portal or mobile app anytime, anywhere.
SPECIFICATIONS
Brand | Cyberpower |
Color | Black |
GENERAL | |
Phase | Single Phase |
Form Factor | Tower |
UPS Topology | Online Double Conversion |
Energy Saving Technology | Online ECO Mode Efficiency > 95% |
Active PFC Compatibility | Yes |
INPUT | |
Generator Compatibility | Yes |
Nominal Input Voltage ( Vac ) | 220 ± 25% |
Input Voltage Range ( Vac ) | 110 ~ 300 |
Input Frequency ( Hz ) | 50 ± 10 60 ± 10 |
Input Frequency Detection | Auto-sensing |
Rated Input Current ( A ) | 13.04 |
Input Power Factor | 0.98 |
Input Connector Type | IEC C20 |
Detachable Power Cord Plug Type | NEMA 5-15P x 1 |
Power Cord Length (ft.) | 5 |
Power Cord Length (m.) | 1.5 |
OUTPUT | |
Capacity (VA) | 3000 |
Capacity (Watts) | 2400 |
On Battery Waveform | Pure Sine Wave |
On Battery Voltage(s) ( Vac ) | 208 ± 1% 220 ± 1% 230 ± 1% 240 ± 1% |
Output Voltage Setting | Configurable |
On Battery Frequency ( Hz ) | 50 ± 0.5% 60 ± 0.5% |
Output Frequency Setting | Configurable |
Power Factor | 0.8 |
ECO Mode Voltage Tolerance | ± 15 % |
Overload Protection | Internal Current Limiting, Circuit Breaker, Fuse |
Overload Protection (Line Mode) | 110~120% Load for 1 min, >120% Load Immediately |
Overload Protection (Battery Mode) | 110~120% Load for 10 sec, >120% Load Immediately |
Overload Protection (Bypass Mode) | >130% Load Immediately |
Crest Factor | 03:01 |
Harmonic Distortion (Linear Load) | THD<3% |
Harmonic Distortion (Non-linear Load) | THD<5% |
Internal Bypass | Automatic Bypass, Manual Bypass |
Outlet(s) – Total | 7 |
Outlet Type | AS x 4 Hardwire Terminal Block x 1 IEC C13 x 2 |
Outlet(s) – Battery & Surge Protected | 6 |
Typical Transfer Time ( ms ) | 0 |
BATTERY | |
Runtime at Half Load ( min ) | 10 |
Runtime at Full Load ( min ) | 4 |
Typical Recharge Time ( Hours ) | 4 |
Maximum Charging Current ( A ) | 1 |
Start On Battery | Yes |
Smart Battery Management (SBM) | Yes |
User-replaceable | No |
Battery Type | Sealed Lead-acid |
SURGE PROTECTION & FILTERING | |
Surge Suppression ( Joules ) | 370 |
EMI/RFI Filtration | Yes |
MANAGEMENT & COMMUNICATIONS | |
LCD Panel | Yes |
LCD Types | Color LCD |
LCD Information Display | Operation Type, Power Status, Battery Status, Load Status, Fault & Warning, Other Information, Event & Log |
LCD Setting & Control | Mode Setting, Alarm Setting, Input & Output, Battery Setting |
HID Compliant USB Port(s) | 1 |
Audible Alarms | Battery Mode, Low Battery, Overload, Overcharge, Overheat, UPS Fault, Replace Battery |
Management Cable ( pcs ) | Power Cord x2, USB Cable x1 |
Power Management Software | PowerPanel Business (Recommended) |
SNMP/HTTP Remote Monitoring | Yes – with optional RMCARD205 |
PHYSICAL | |
Enclosure Construction | Metal |
PHYSICAL SIZE – UPS MODULE | |
Dimensions (WxHxD) (in.) | 7.72 x 12.27 x 16.38 |
Dimensions (WxHxD) (mm.) | 196 x 337 x 416 |
Weight (lbs.) | 57.2 |
Weight (kg.) | 26 |
ENVIRONMENTAL | |
Operating Temperature (°F) | 32 ~ 104 |
Operating Temperature (°C) | 0 ~ 40 |
Operating Relative Humidity (Non-condensing) ( % ) | 20 ~ 90 |
Operating Elevation ( feet/meters ) | 0-4,921 feet (0-1,500 meters) |
Storage Temperature (°F) |  -4 ~ 122 |
Storage Temperature (°C) |  -20 ~ 50 |
Storage Relative Humidity (Non-condensing) ( % ) | 10 ~ 90 |
Storage Elevation ( feet/meters ) | 0-4,921 feet (0-1,500 meters) |
Online Thermal Dissipation ( BTU/hr ) | 712 |
Variable Speed Fans | 20 steps automatically |
CERTIFICATIONS | |
Certifications | CE |
RoHS | Yes |
Warranty | 2 Years |
Note | * Features, Price, Specifications are subject to change without notice. |
One Click to Visit Our Social Media Handle → Instagram
Reviews
There are no reviews yet.